Electric Actuated Stainless 3 Way GE Ball Valve On Off :

  • Overview - The 3 way ball valve is designed for actuation with an integrallly cast ISO5211 actuator pad. GE reduced bore stainless steel ball valves with BSP female treaded end connnections are available as a 3 way L port for diverting duties ora 3 way T port for diverting or mixing duties. Supplied fully assembled and dry bench function tested by J+J in Matlock, Derbyshire.
  • Function - J3C-S on-off smart electric actuators are designed for power to open and power to close. Stays put on external power failure. Designed to have power applied continuously.
  • Sizing Criteria - J3CS Electrical on-off actuators have been sized on a wet service with a maximum pressure of 16bar at max +70C. If your intended duty differs from this please contact us to confirm the correct actuated ball valve for your particular application.
  • Options - Available L port or T port. Max +130C service using a mounting kit.


Electric Actuated Stainless 3 Way GE Ball Valve Failsafe :

  • Overview - The 3 way ball valve is designed for actuation with an integrallly cast ISO5211 actuator pad. GE reduced bore stainless steel ball valves with BSP female treaded end connnections are available as a 3 way L port for diverting duties ora 3 way T port for diverting or mixing duties. Supplied fully assembled and dry bench function tested by J+J in Matlock, Derbyshire.
  • Function - J3C-S BSR smart failsafe electric actuators are designed for power to open and power to close, but fails to pre-determined position on external power failure using an internal battery. Designed to have power applied continuously.
  • Sizing Criteria - J3CS Electrical failsafe actuators have been sized on a wet service with a maximum pressure of 16bar at max +70C. If your intended duty differs from this please contact us to confirm the correct actuated ball valve for your particular application.
  • Options - Available L port or T port. Can be configured fail open, or fail closed. Max +130C service using a mounting kit.


Electric Actuated Stainless 3 Way GE Ball Valve Modulating :

  • Overview - The 3 way ball valve is designed for actuation with an integrallly cast ISO5211 actuator pad. GE reduced bore stainless steel ball valves with BSP female treaded end connnections are available as a 3 way L port for diverting duties ora 3 way T port for diverting or mixing duties. Supplied fully assembled and dry bench function tested by J+J in Matlock, Derbyshire.
  • Function - J3C-S DPS smart modulating electric actuators are designed to move proportional to an input control signal with power applied continuously. They provide an output signal as standard. Fails to pre-set position on loss of control signal, stays put on loss of external power.
  • Sizing Criteria - J3CS Electrical modulating actuators have been sized on a wet service with a maximum pressure of 16bar at max +70C. If your intended duty differs from this please contact us to confirm the correct actuated ball valve for your particular application.
  • Options - Available L port or T port. Can be configured to stay put, fail open, or fail closed on loss of control signal. Stays put on loss of external power. Max +130C service using a mounting kit.


Electric Actuated Stainless 3 Way GE Ball Valve Failsafe Modulating :

  • Overview - The 3 way ball valve is designed for actuation with an integrallly cast ISO5211 actuator pad. GE reduced bore stainless steel ball valves with BSP female treaded end connnections are available as a 3 way L port for diverting duties ora 3 way T port for diverting or mixing duties. Supplied fully assembled and dry bench function tested by J+J in Matlock, Derbyshire.
  • Function - J3C-S DPS BSR failsafe modulating smart electric actuators are designed to move proportional to an input control signal with power applied continuously. They provide an output signal as standard. Fails to pre-set position on loss of control signal, and on loss of external power.
  • Sizing Criteria - J3CS Electrical failsafe modulating actuators have been sized on a wet service with a maximum pressure of 16bar at max +70C. If your intended duty differs from this please contact us to confirm the correct actuated ball valve for your particular application.
  • Options - Available L port or T port. Can be configured to stay put, fail open, or fail closed on loss of control signal. Can be configured to fail open, or fail closed on loss of external power. Max +130C service using a mounting kit.